Address:
162 SANTA BARBARA ST, GUADALUPE, CA 93434
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
500'
Required Method:
1/150
Calculation:
500 ÷ 150 = 3.33 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
3.33
Calculation:
3.33 x 144 = 479.52 sq. in of Code Required Ventilation
Square Inches Provided:
(6 x 97.5) = 585 sq. in
Square Inches Needed:
3.33 x 144 = 479.52 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
3
Low / Intake Vents Needed:
3
Total Vents Needed:
6
clay Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Wire Mesh 97.5 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing
Questions?