Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
749'
Required Method:
1/150
Calculation:
749 ÷ 150 = 4.99 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
4.99
Calculation:
4.99 x 144 = 718.56 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
concrete Tile
Placement
Square Inches Provided:
(10 x 72) = 720 sq. in
Square Inches Needed:
4.99 x 144 = 718.56 sq. in
High / Exhaust Vents Needed:
5
Low / Intake Vents Needed:
5
Total Vents Needed:
10