Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
580'
Required Method:
1/150
Calculation:
580 ÷ 150 = 3.87 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
3.87
Calculation:
3.87 x 144 = 557.28 sq. in of Code Required Ventilation
Square Inches Provided:
(6 x 86.25) = 517.5 sq. in
Square Inches Needed:
3.87 x 144 = 557.28 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
3
Low / Intake Vents Needed:
3
Total Vents Needed:
6
clay Tile Vents
Medium Profile (M)
NET FREE VENTILATION AREA
Wire Mesh 86.25 sq. in
Figures based on independent evaluation reports.