Address:
5528 Calumet Avenue, San Diego CA United States 1ST STORY
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
797'
Required Method:
1/300
Calculation:
797 ÷ 300 = 2.66 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
2.66
Calculation:
2.66 x 144 = 383.04 sq. in of Code Required Ventilation
Square Inches Provided:
(6 x 72) = 432 sq. in
Square Inches Needed:
2.66 x 144 = 383.04 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
3
Low / Intake Vents Needed:
3
Total Vents Needed:
6
Composition shingle
Low Profile (Tapered)
NET FREE VENTILATION AREA
Wire Mesh 72 sq. in
Figures based on independent evaluation reports.