Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
850'
Required Method:
1/150
Calculation:
850 ÷ 150 = 5.67 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
5.67
Calculation:
5.67 x 144 = 816.48 sq. in of Code Required Ventilation
Square Inches Provided:
(10 x 86.25) = 862.5 sq. in
Square Inches Needed:
5.67 x 144 = 816.48 sq. in
Vent Placement
High / Exhaust Vents Needed:
5
Low / Intake Vents Needed:
5
Total Vents Needed:
10
concrete Tile Vents
Medium Profile (M)
NET FREE VENTILATION AREA
Wire Mesh
86.25 sq. in
Figures based on independent evaluation reports.