5060 Dolphin Way, Oxnard, CA
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
602'
Required Method:
1/150
Calculation:
602 ÷ 150 = 4.01 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
4.01
Calculation:
4.01 x 144 = 577.44 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
Composition shingle
Placement
Square Inches Provided:
(6 x 98.75) = 592.5 sq. in
Square Inches Needed:
4.01 x 144 = 577.44 sq. in
High / Exhaust Vents Needed:
3
Low / Intake Vents Needed:
3
Total Vents Needed:
6