Total Vents (Exhaust & Intake):
14
“Where do I install the vents?”
Vent Placement Recommendations
High / Exhaust — Off-Ridge Vents:
(Install within 3' of Ridge Assembly)
(Min. 40% / Max. 50%)
7
Low / Intake — Off-Ridge Vents:
(Install within Lower 1/3 of Attic)
(Min. 50% / Max. 60%)
7
Comp Roof Drawing

Roofing Material Manufacturer Warranties Require the Compliance with Building Code Attic Ventilation Formulas

Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1,828
Code Required Method:
1/300 (EXCEPTION)
Calculation:
1,828 ÷ 300 = 6.09 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
6.09
Calculation:
6.09 x 144 = 876.96 sq. in. of Code Required Ventilation
Square Inches Provided:
Off-Ridge (14 x 72) = 1,008 sq. in.