Address:
1560 E Rd 2 North, Chino Valley, AZ
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1960'
Required Method:
1/300
Calculation:
1960 ÷ 300 = 6.53 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
6.53
Calculation:
6.53 x 144 = 940.32 sq. in of Code Required Ventilation
Square Inches Provided:
(10 x 98.75) = 987.5 sq. in
Square Inches Needed:
6.53 x 144 = 940.32 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
5
Low / Intake Vents Needed:
5
Total Vents Needed:
10
Composition shingle
Low Profile (Tapered)
NET FREE VENTILATION AREA
Wire Mesh 98.75 sq. in
Figures based on independent evaluation reports.
Comp Roof Drawing
Questions?