Contact Us
(877) 324-0444
Search
Products
Composition Shingle Vents
Clay Tile Vents
Concrete Tile Vents
Natural Slate Vents
Synthetic Shake and Slate Vents
Wood Shake Vents
Universal Direct Deck
Fire&Ice® Vents
Fire&Ice® Profile Specific Vents for Concrete, Clay & Synthetic Tile Roofs
Fire&Ice® Composition Shingle, Synthetic Shake & Slate Vents
Gallery
Services
Pre-Construction Services
Attic Ventilation Analysis Request Form
Benefits of Attic Ventilation
O’Hagin University
AIA Approved Continuing Education
Resources
Approvals
Architectural Resources & Drawings
Building Codes
Find a Distributor
Installation Instructions
Limited Warranty
Technical Bulletins
Vent Calculator
Search
Back to Vent Calculator
Print
Address:
1800 Hemlock Street, Chico CA 95928
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2000'
Required Method:
1/300
Calculation:
2000 ÷ 300 = 6.67 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
6.67
Calculation:
6.67 x 144 = 960.48 sq. in of Code Required Ventilation
Square Inches Provided:
(20 x 98.75) = 1975 sq. in
Square Inches Needed:
6.67 x 144 = 960.48 sq. in
Vent Placement
High / Exhaust Vents Needed:
10
Low / Intake Vents Needed:
10
Total Vents Needed:
20
Composition shingle
Low Profile (Tapered)
NET FREE VENTILATION AREA
Wire Mesh
98.75 sq. in
Figures based on independent evaluation reports.