Address:
25738 LETICIA DR.
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
459'
Required Method:
1/150
Calculation:
459 ÷ 150 = 3.06 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
3.06
Calculation:
3.06 x 144 = 440.64 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
clay Tile
Placement
Square Inches Provided:
(6 x 98.75) = 592.5 sq. in
Square Inches Needed:
3.06 x 144 = 440.64 sq. in
High / Exhaust Vents Needed:
3
Low / Intake Vents Needed:
3
Total Vents Needed:
6
Material:
clay Tile
Product:
Low Profile - "Flat"
Tile Roof Drawing