Total Vents:
78
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
39
Low / Intake Vents:
(Within Lower 1/3 of Attic)
39
Comp Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
5,800
Code Required Method:
1/150 (STANDARD)
Calculation:
5,800 ÷ 150 = 38.67 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
38.67
Calculation:
38.67 x 144 = 5,568.48 sq. in. of Code Required Ventilation
Square Inches Provided:
(78 x 72) = 5,616 sq. in.
synthetic Shake and Slate Vents
Low Profile (Tapered)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 72 sq. in.
Figures based on independent evaluation reports.