Address:
1909 Business Center Drive South San Bernardino, CA 92408
Total Vents:
46
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
23
Low / Intake Vents:
(Within Lower 1/3 of Attic)
23
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
9,052
Code Required Method:
1/300 (EXCEPTION)
Calculation:
9,052 ÷ 300 = 30.17 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
30.17
Calculation:
30.17 x 144 = 4,344.48 sq. in. of Code Required Ventilation
Square Inches Provided:
(46 x 97.50) = 4,485 sq. in.
clay Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 97.50 sq. in.
Figures based on independent evaluation reports.
Vent Solutions
Questions?