Total Vents:
368
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
184
Low / Intake Vents:
(Within Lower 1/3 of Attic)
184
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
37,200
Code Required Method:
1/150 (STANDARD)
Calculation:
37,200 ÷ 150 = 248 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
248
Calculation:
248 x 144 = 35,712 sq. in. of Code Required Ventilation
Square Inches Provided:
(368 x 97.50) = 35,880 sq. in.
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 97.50 sq. in.
Figures based on independent evaluation reports.