Address:
9370 S Old Soldier Trail, Vail, AZ 85641
Total Vents:
32
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
16
Low / Intake Vents:
(Within Lower 1/3 of Attic)
16
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2,810
Code Required Method:
1/150 (STANDARD)
Calculation:
2,810 ÷ 150 = 18.73 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
18.73
Calculation:
18.73 x 144 = 2,697.12 sq. in. of Code Required Ventilation
Square Inches Provided:
(32 x 88.87) = 2,843.84 sq. in.
concrete Tile Vents
Low Profile (Flat)
NET FREE VENTILATION AREA
1/8" Noncombustible, Corrosion-Resistant Wire Mesh 88.87 sq. in.
Figures based on independent evaluation reports.