Address:
16656 Cumbre Verde ct
Total Vents:
46
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
23
Low / Intake Vents:
(Within Lower 1/3 of Attic)
23
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
4,017
Code Required Method:
1/150 (STANDARD)
Calculation:
4,017 ÷ 150 = 26.78 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
26.78
Calculation:
26.78 x 144 = 3,856.32 sq. in. of Code Required Ventilation
Square Inches Provided:
(46 x 86.25) = 3,967.50 sq. in.
clay Tile Vents
Medium Profile (M)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 86.25 sq. in.