Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
5448'
Required Method:
1/300
Calculation:
5448 ÷ 300 = 18.16 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
18.16
Calculation:
18.16 x 144 = 2615.04 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
concrete Tile
Placement
Square Inches Provided:
(28 x 86.25) = 2415 sq. in
Square Inches Needed:
18.16 x 144 = 2615.04 sq. in
High / Exhaust Vents Needed:
14
Low / Intake Vents Needed:
14
Total Vents Needed:
28
Material:
concrete Tile
Product:
Medium Profile - "M"
Tile Roof Drawing
Benefits of Attic Ventilation
1. Extends the roof's life
2. Curb appeal
3. Balanced System
4. Fits with Solar Systems
5. Validate the Warranty
6. Enhances Above-Sheathing Ventilation (ASV)
7. Reduces Moisture/Removes Trapped Gases
8. Energy conservation