Address:
2995 Sonrisa Drive, Corona, CA, 92881
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
3206'
Required Method:
1/300
Calculation:
3206 ÷ 300 = 10.69 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
10.69
Calculation:
10.69 x 144 = 1539.36 sq. in of Code Required Ventilation
Square Inches Provided:
(16 x 86.25) = 1380 sq. in
Square Inches Needed:
10.69 x 144 = 1539.36 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
8
Low / Intake Vents Needed:
8
Total Vents Needed:
16
concrete Tile Vents
Medium Profile (M)
NET FREE VENTILATION AREA
Tile Profile Medium (M)
Wire Mesh 86.25 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing