Address:
3768 Royal Meadow Road Sherman Oaks, CA
Total Vents:
28
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
14
Low / Intake Vents:
(Within Lower 1/3 of Attic)
14
Comp Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2,692
Code Required Method:
1/150 (EXCEPTION)
Calculation:
2,692 ÷ 150 = 17.95 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
17.95
Calculation:
17.95 x 144 = 2,584.80 sq. in. of Code Required Ventilation
Square Inches Provided:
(28 x 98.75) = 2,765 sq. in.
Composition shingle
Low Profile (Tapered)
NET FREE VENTILATION AREA
Noncombustible, Corrosion-Resistant Wire Mesh 98.75 sq. in.
Figures based on independent evaluation reports.
Vent Solutions