Roofing Material Manufacturer Warranties Require the Compliance with Building Code Attic Ventilation Formulas

Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
8,368
Code Required Method:
1/150 (STANDARD)
Calculation:
8,368 ÷ 150 = 55.79 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
55.79
Calculation:
55.79 x 144 = 8,033.76 sq. in. of Code Required Ventilation
Square Inches Provided:
Off-Ridge (116 x 70.20) = 8,143.20 sq. in.