Address:
18527 Santa Andrea St Fountain Valley CA USA 92708
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
431'
Required Method:
1/300
Calculation:
431 ÷ 300 = 1.44 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
1.44
Calculation:
1.44 x 144 = 207.36 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
Composition shingle
Placement
Square Inches Provided:
(4 x 98.75) = 395 sq. in
Square Inches Needed:
1.44 x 144 = 207.36 sq. in
High / Exhaust Vents Needed:
2
Low / Intake Vents Needed:
2
Total Vents Needed:
4
Material:
Composition shingle
Product:
Low Profile - "Tapered"
Comp Roof Drawing