Address:
20920 North 80th Avenue, Peoria AZ, 85382
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2430'
Required Method:
1/150
Calculation:
2430 ÷ 150 = 16.20 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
16.20
Calculation:
16.20 x 144 = 2332.80 sq. in of Code Required Ventilation
Square Inches Provided:
(24 x 97.5) = 2340 sq. in
Square Inches Needed:
16.20 x 144 = 2332.80 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
12
Low / Intake Vents Needed:
12
Total Vents Needed:
24
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Tile Profile High (S)
Wire Mesh 97.5 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing
Questions?