Address:
1983 RUDOLPH DRIVE, THOUSAND OAKS, DA
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
424'
Required Method:
1/150
Calculation:
424 ÷ 150 = 2.83 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
2.83
Calculation:
2.83 x 144 = 407.52 sq. in of Code Required Ventilation
Square Inches Provided:
(6 x 97.5) = 585 sq. in
Square Inches Needed:
2.83 x 144 = 407.52 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
3
Low / Intake Vents Needed:
3
Total Vents Needed:
6
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Wire Mesh 97.5 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing
Questions?