Address:
5229 Shore Drive, Carlsbad - non fire zone
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1742'
Required Method:
1/300
Calculation:
1742 ÷ 300 = 5.81 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
5.81
Calculation:
5.81 x 144 = 836.64 sq. in of Code Required Ventilation
Square Inches Provided:
(10 x 97.5) = 975 sq. in
Square Inches Needed:
5.81 x 144 = 836.64 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
5
Low / Intake Vents Needed:
5
Total Vents Needed:
10
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Wire Mesh 97.5 sq. in
Figures based on independent evaluation reports.