Address:
10225 S. JAMESON AVE FRESNO, CA 93706
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1227'
Required Method:
1/150
Calculation:
1227 ÷ 150 = 8.18 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
8.18
Calculation:
8.18 x 144 = 1177.92 sq. in of Code Required Ventilation
Square Inches Provided:
(0 x 72) = 0 sq. in
Square Inches Needed:
8.18 x 144 = 1177.92 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
0
Low / Intake Vents Needed:
0
Total Vents Needed:
0
concrete Tile Vents
Low Profile (Flat)
NET FREE VENTILATION AREA
Wire Mesh 72 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing
Questions?