Address:
7827 Crest Hammock Way, Sarasota, FL 34240
Total Vents:
64
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
32
Low / Intake Vents:
(Within Lower 1/3 of Attic)
32
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
5,638
Code Required Method:
1/150 (EXCEPTION)
Calculation:
5,638 ÷ 150 = 37.59 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
37.59
Calculation:
37.59 x 144 = 5,412.96 sq. in. of Code Required Ventilation
Square Inches Provided:
(64 x 86.25) = 5,520 sq. in.
concrete Tile Vents
Medium Profile (M)
NET FREE VENTILATION AREA
Noncombustible, Corrosion-Resistant Wire Mesh 86.25 sq. in.