Total Square Feet of Attic Space to be Ventilated:
3317'
Required Method:
1/150
Calculation:
3317 ÷ 150 = 22.11 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
22.11
Calculation:
22.11 x 144 = 3183.84 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
concrete Tile
Placement
Square Inches Provided:
(34 x 97.5) = 3315 sq. in
Square Inches Needed:
22.11 x 144 = 3183.84 sq. in
High / Exhaust Vents Needed:
17
Low / Intake Vents Needed:
17
Total Vents Needed:
34
Material:
concrete Tile
Product:
High Profile - "S"
Benefits of Attic Ventilation
1. Extends the roof's life
2. Curb appeal
3. Balanced System
4. Fits with Solar Systems
5. Validate the Warranty
6. Enhances Above-Sheathing Ventilation (ASV)
7. Reduces Moisture/Removes Trapped Gases
8. Energy conservation