Address:
1817 Acacia Lane, Fallbrook - Garage/House (one attic)
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2963'
Required Method:
1/150
Calculation:
2963 ÷ 150 = 19.75 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
19.75
Calculation:
19.75 x 144 = 2844.00 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
Composition shingle
Placement
Square Inches Provided:
(40 x 72) = 2880 sq. in
Square Inches Needed:
19.75 x 144 = 2844.00 sq. in
High / Exhaust Vents Needed:
20
Low / Intake Vents Needed:
20
Total Vents Needed:
40