Address:
690 SIERRA MEDOW DRIVE SIERRA MADRE CA 91024 (GARAGE)
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
468'
Required Method:
1/300
Calculation:
468 ÷ 300 = 1.56 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
1.56
Calculation:
1.56 x 144 = 224.64 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
Composition shingle
Placement
Square Inches Provided:
(4 x 72) = 288 sq. in
Square Inches Needed:
1.56 x 144 = 224.64 sq. in
High / Exhaust Vents Needed:
2
Low / Intake Vents Needed:
2
Total Vents Needed:
4
Material:
Composition shingle
Product:
Low Profile - "Tapered"
Comp Roof Drawing