Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1550'
Required Method:
1/150
Calculation:
1550 ÷ 150 = 10.33 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
10.33
Calculation:
10.33 x 144 = 1487.52 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
Composition shingle
Placement
Square Inches Provided:
(22 x 72) = 1584 sq. in
Square Inches Needed:
10.33 x 144 = 1487.52 sq. in
High / Exhaust Vents Needed:
11
Low / Intake Vents Needed:
11
Total Vents Needed:
22
Material:
Composition shingle
Product:
Low Profile - "Tapered"
Comp Roof Drawing