Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
3752'
Required Method:
1/300
Calculation:
3752 ÷ 300 = 12.51 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
12.51
Calculation:
12.51 x 144 = 1801.44 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
concrete Tile
Placement
Square Inches Provided:
(20 x 97.5) = 1950 sq. in
Square Inches Needed:
12.51 x 144 = 1801.44 sq. in
High / Exhaust Vents Needed:
10
Low / Intake Vents Needed:
10
Total Vents Needed:
20
Material:
concrete Tile
Product:
High Profile - "S"
Tile Roof Drawing