Address:
250 W Juniper Ave 56
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1700'
Required Method:
1/300
Calculation:
1700 ÷ 300 = 5.67 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
5.67
Calculation:
5.67 x 144 = 816.48 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
concrete Tile
Placement
Square Inches Provided:
(10 x 86.25) = 862.5 sq. in
Square Inches Needed:
5.67 x 144 = 816.48 sq. in
High / Exhaust Vents Needed:
5
Low / Intake Vents Needed:
5
Total Vents Needed:
10
Material:
concrete Tile
Product:
Medium Profile - "M"
Tile Roof Drawing
Benefits of Attic Ventilation
1. Extends the roof's life
2. Curb appeal
3. Balanced System
4. Fits with Solar Systems
5. Validate the Warranty
6. Enhances Above-Sheathing Ventilation (ASV)
7. Reduces Moisture/Removes Trapped Gases
8. Energy conservation