Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
3800'
Required Method:
1/300
Calculation:
3800 ÷ 300 = 12.67 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
12.67
Calculation:
12.67 x 144 = 1824.48 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
concrete Tile
Placement
Square Inches Provided:
(20 x 86.25) = 1725 sq. in
Square Inches Needed:
12.67 x 144 = 1824.48 sq. in
High / Exhaust Vents Needed:
10
Low / Intake Vents Needed:
10
Total Vents Needed:
20
Material:
concrete Tile
Product:
Medium Profile - "M"
Tile Roof Drawing