Total Vents:
1524
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
762
Low / Intake Vents:
(Within Lower 1/3 of Attic)
762
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
154,600
Code Required Method:
1/150 (STANDARD)
Calculation:
154,600 ÷ 150 = 1,030.67 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
1,030.67
Calculation:
1,030.67 x 144 = 148,416.48 sq. in. of Code Required Ventilation
Square Inches Provided:
(1,524 x 97.50) = 148,590 sq. in.
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 97.50 sq. in.
Figures based on independent evaluation reports.
Vent Solutions
Questions?