Address:
5217 West Neptune Way Tampa
Total Vents:
76
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
38
Low / Intake Vents:
(Within Lower 1/3 of Attic)
38
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
7,702
Code Required Method:
1/150 (STANDARD)
Calculation:
7,702 ÷ 150 = 51.35 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
51.35
Calculation:
51.35 x 144 = 7,394.40 sq. in. of Code Required Ventilation
Square Inches Provided:
(76 x 97.50) = 7,410 sq. in.
clay Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 97.50 sq. in.
Figures based on independent evaluation reports.