Address:
643 castleridge Dr. Fort Collins CO
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
5457'
Required Method:
1/150
Calculation:
5457 ÷ 150 = 36.38 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
36.38
Calculation:
36.38 x 144 = 5238.72 sq. in of Code Required Ventilation
Square Inches Provided:
(62 x 97.5) = 6045 sq. in
Square Inches Needed:
36.38 x 144 = 5238.72 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
31
Low / Intake Vents Needed:
31
Total Vents Needed:
62
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Wire Mesh 97.5 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing
Questions?