Address:
33525 Buckwheat Road, Menifee, CA, 92584
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
3325'
Required Method:
1/300
Calculation:
3325 ÷ 300 = 11.08 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
11.08
Calculation:
11.08 x 144 = 1595.52 sq. in of Code Required Ventilation
Square Inches Provided:
(20 x 97.5) = 1950 sq. in
Square Inches Needed:
11.08 x 144 = 1595.52 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
10
Low / Intake Vents Needed:
10
Total Vents Needed:
20
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Tile Profile High (S)
Wire Mesh 97.5 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing
Questions?