Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
9,190
Code Required Method:
1/300 (EXCEPTION)
Calculation:
9,190 ÷ 300 = 30.63 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
30.63
Calculation:
30.63 x 144 = 4,410.72 sq. in. of Code Required Ventilation
Square Inches Provided:
(46 x 97.50) = 4,485 sq. in.
concrete Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 97.50 sq. in.
Figures based on independent evaluation reports.