Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
361'
Required Method:
1/150
Calculation:
361 ÷ 150 = 2.41 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
2.41
Calculation:
2.41 x 144 = 347.04 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
Composition shingle
Placement
Square Inches Provided:
(4 x 98.75) = 395 sq. in
Square Inches Needed:
2.41 x 144 = 347.04 sq. in
High / Exhaust Vents Needed:
2
Low / Intake Vents Needed:
2
Total Vents Needed:
4
Material:
Composition shingle
Product:
Low Profile - "Tapered"
Comp Roof Drawing