Address:
1043 S Pleasant St., Boulder, CO., 80302
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2475'
Required Method:
1/300
Calculation:
2475 ÷ 300 = 8.25 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation
8.25
Calculation:
8.25 x 144 = 1188.00 sq. in of Code Required Ventilation
Select Material and Determine Vents Required
Material:
concrete Tile
Placement
Square Inches Provided:
(