Address:
207 Belvidere Dr, San Antonio, TX 78212
Total Vents:
20
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
10
Low / Intake Vents:
(Within Lower 1/3 of Attic)
10
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1,849
Code Required Method:
1/150 (EXCEPTION)
Calculation:
1,849 ÷ 150 = 12.33 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
12.33
Calculation:
12.33 x 144 = 1,775.52 sq. in. of Code Required Ventilation
Square Inches Provided:
(20 x 88.87) = 1,777.40 sq. in.
clay Tile Vents
Low Profile (Flat)
NET FREE VENTILATION AREA
1/8" Noncombustible, Corrosion-Resistant Wire Mesh 88.87 sq. in.
Figures based on independent evaluation reports.