Address:
22308 WHIRLAWAY CT, CANYON LAKE, CA 92673
Total Vents:
22
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
11
Low / Intake Vents:
(Within Lower 1/3 of Attic)
11
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
3,684
Code Required Method:
1/300 (EXCEPTION)
Calculation:
3,684 ÷ 300 = 12.28 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
12.28
Calculation:
12.28 x 144 = 1,768.32 sq. in. of Code Required Ventilation
Square Inches Provided:
(22 x 87.75) = 1,930.50 sq. in.
clay Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
1/8" Noncombustible, Corrosion-Resistant Wire Mesh 87.75 sq. in.
Figures based on independent evaluation reports.