Address:
6 BREAKER CT. Shelter Cove, CA 95589
Total Vents:
14
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
7
Low / Intake Vents:
(Within Lower 1/3 of Attic)
7
Metal Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1,067
Code Required Method:
1/150 (EXCEPTION)
Calculation:
1,067 ÷ 150 = 7.11 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
7.11
Calculation:
7.11 x 144 = 1,023.84 sq. in. of Code Required Ventilation
Square Inches Provided:
(14 x 78) = 1,092 sq. in.
Standing Seam metal
Low Profile (Tapered)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 78 sq. in.
Figures based on independent evaluation reports.