Address:
3325 Via Verde Ct • Calabasas, CA 91302
Total Vents:
44
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
22
Low / Intake Vents:
(Within Lower 1/3 of Attic)
22
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
4,000
Code Required Method:
1/150 (EXCEPTION)
Calculation:
4,000 ÷ 150 = 26.67 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
26.67
Calculation:
26.67 x 144 = 3,840.48 sq. in. of Code Required Ventilation
Square Inches Provided:
(44 x 88.87) = 3,910.28 sq. in.
clay Tile Vents
Low Profile (Flat)
NET FREE VENTILATION AREA
1/8" Noncombustible, Corrosion-Resistant Wire Mesh 88.87 sq. in.
Figures based on independent evaluation reports.
Vent Solutions
Questions?