Address:
11926 Royce Waterford Circle Tampa, FL 33626
Total Vents:
28
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
14
Low / Intake Vents:
(Within Lower 1/3 of Attic)
14
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
4,773
Code Required Method:
1/300 (EXCEPTION)
Calculation:
4,773 ÷ 300 = 15.91 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
15.91
Calculation:
15.91 x 144 = 2,291.04 sq. in. of Code Required Ventilation
Square Inches Provided:
(28 x 86.25) = 2,415 sq. in.
concrete Tile Vents
Medium Profile (M)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 86.25 sq. in.
Figures based on independent evaluation reports.