Address:
7135 E Camelback Rd - Waterfront
Total Vents:
222
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
111
Low / Intake Vents:
(Within Lower 1/3 of Attic)
111
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
39,850
Code Required Method:
1/300 (EXCEPTION)
Calculation:
39,850 ÷ 300 = 132.83 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
132.83
Calculation:
132.83 x 144 = 19,127.52 sq. in. of Code Required Ventilation
Square Inches Provided:
(222 x 86.25) = 19,147.50 sq. in.
clay Tile Vents
Medium Profile (M)
NET FREE VENTILATION AREA
1/4" Noncombustible, Corrosion-Resistant Wire Mesh 86.25 sq. in.
Figures based on independent evaluation reports.
Vent Solutions
Questions?