Back to Vent Calculator
Print
Total Vents:
16
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
8
Low / Intake Vents:
(Within Lower 1/3 of Attic)
8
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2,700
Code Required Method:
1/300 (EXCEPTION)
Calculation:
2,700 ÷ 300 = 9 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
9
Calculation:
9 x 144 = 1,296 sq. in. of Code Required Ventilation
Square Inches Provided:
(16 x 88.87) = 1,421.92 sq. in.
clay Tile Vents
Low Profile (Flat)
NET FREE VENTILATION AREA
1/8" Noncombustible, Corrosion-Resistant Wire Mesh
88.87 sq. in.
Figures based on independent evaluation reports.