Address:
11153 59th Avenue Seminole 33772
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2172'
Required Method:
1/300
Calculation:
2172 ÷ 300 = 7.24 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
7.24
Calculation:
7.24 x 144 = 1042.56 sq. in of Code Required Ventilation
Square Inches Provided:
(12 x 97.5) = 1170 sq. in
Square Inches Needed:
7.24 x 144 = 1042.56 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
6
Low / Intake Vents Needed:
6
Total Vents Needed:
12
clay Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Wire Mesh 97.5 sq. in
Figures based on independent evaluation reports.
Tile Roof Drawing
Questions?