Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
2345'
Required Method:
1/150
Calculation:
2345 ÷ 150 = 15.63 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
15.63
Calculation:
15.63 x 144 = 2250.72 sq. in of Code Required Ventilation
Square Inches Provided:
(34 x 70.2) = 2386.8 sq. in
Square Inches Needed:
15.63 x 144 = 2250.72 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
17
Low / Intake Vents Needed:
17
Total Vents Needed:
34
metal
Low Profile (Tapered)
NET FREE VENTILATION AREA
Wire Mesh 70.2 sq. in
Figures based on independent evaluation reports.
Metal Roof Drawing