2412 Primrose Avenue, Vista - Fire Zone (within 1 mile)
Total Vents:
12
Where do I install vents graphic
Vent Placement Recommendations
High / Exhaust Vents Needed:
(Within 3' of Ridge Assembly)
6
Low / Intake Vents:
(Within Lower 1/3 of Attic)
6
Tile Roof Drawing
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
1,041
Code Required Method:
1/150 (EXCEPTION)
Calculation:
1,041 ÷ 150 = 6.94 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
6.94
Calculation:
6.94 x 144 = 999.36 sq. in. of Code Required Ventilation
Square Inches Provided:
(12 x 97.50) = 1,170 sq. in.
clay Tile Vents
High Profile (S)
NET FREE VENTILATION AREA
Noncombustible, Corrosion-Resistant Wire Mesh 97.50 sq. in.
Figures based on independent evaluation reports.
Vent Solutions