Address:
752 W El Morado Ct Ontario 91762
Total Square Feet of Attic Space to be Ventilated
Total Square Feet of Attic Space to be Ventilated:
363'
Required Method:
1/150
Calculation:
363 ÷ 150 = 2.42 sq. ft. of Code Required Ventilation
Convert square feet of code-required ventilation to square inches
Square Feet of Code Required Ventilation:
2.42
Calculation:
2.42 x 144 = 348.48 sq. in of Code Required Ventilation
Square Inches Provided:
(6 x 72) = 432 sq. in
Square Inches Needed:
2.42 x 144 = 348.48 sq. in
Where do I install vents graphic
Vent Placement
High / Exhaust Vents Needed:
3
Low / Intake Vents Needed:
3
Total Vents Needed:
6
Composition shingle
Low Profile (Tapered)
NET FREE VENTILATION AREA
Wire Mesh 72 sq. in
Figures based on independent evaluation reports.